TEC SX Series Sensor Calibration
Follow the steps outlined below for Calibration Procedures of tag media used on the TEC SX-4 and SX-5 series printer models
RAM Clears
- Turn printer off.
- Press and hold the FEED and PAUSE keys and turn the printer on.
- Press the RESTART key until RAM CLEAR shows on the display.
- Press the PAUSE key to display NO RAM CLEAR.
- Press the RESTART key until PARAMETER CLEAR is displayed
- Press the PAUSE key to display QP TYPE.
- Press the RESTART key until QQ TYPE is displayed.
- Press the PAUSE key. The display will show several asterisks and COMPLETE.
- Turn printer off.
- Press and hold the FEED and PAUSE keys and turn the printer on.
- Press the RESTART key until RAM CLEAR shows on the display.
- Press the PAUSE key to display NO RAM CLEAR.
- Press the RESTART key until MAINT CNT CLEAR is displayed.
- Press the PAUSE key. The display will show several asterisks and COMPLETE.
Manual Calibration
NOTE: If colored media is being used, calibrate the sensor with the darkest color being used. Usually RED tags are recommended if using variety of colors.
- Turn printer off.
- Press and hold the FEED and PAUSE keys and turn the printer on.
- Press the FEED key until SENSOR ADJ. shows in display.
- Press the PAUSE key until REFLECT shows in the display.
- Slide the sensor out towards the middle of the tags.
- Place plastic labels under sensor. (SEE NOTE)
- Press and hold the RESTART key until asterisk shows to the right of the digits.
- Should read in the 4.0 ± 0.3 volt range.
- Remove plastic labels from printer.
- Press the PAUSE key until PE shows in the display.
- Make sure there is no material under the sensors.
- Press and hold the RESTART key until an asterisk shows to the right of the digits.
- Turn the printer off.
- Place tags under sensor and position sensor as shown so the reflective sensor is aligned with the notch of the tag being used.
- Close the printhead assembly.
- Power on the printer.
- Once the display shows ONLINE. Press the PAUSE key so the display shows PAUSE.
- Hold in the PAUSE key until TRANS appears on the display.
- Press the FEED key so REFLECT appears on the display.
- Hold in the PAUSE key allow the printer to feed out several tags before releasing.
Auto-Calibration Set Up
- From the PAUSE screen, hold in the RESTART key until the display shows RESET.
- Press the RESTART key until the display shows AUTO CALIB
- Press the PAUSE key to display OFF.
- Press the RESTART key until the display shows ON REFLECT.
- Press the PAUSE key.
- Press the FEED key until the display shows RESET.
- Press the PAUSE key.